STEMM Institute Press
Science, Technology, Engineering, Management and Medicine
Integrated Care to Reduce Contrast Agent Extravasation in CT Enhancement Examinations
DOI: https://doi.org/10.62517/jmhs.202305109
Author(s)
Aiyin Zhang, Yongli Zou*, Yuelu Wang, Lin Zhang, Tengmei Gui, Tingting Tang, Liangqun Cheng, Yuan Zhang, Yan Yuan
Affiliation(s)
Guizhou Provincial People's Hospital, Guiyang550002, Guizhou, Chain * Corresponding Author
Abstract
To explore the effectiveness of integrated care in reducing contrast agent extravasation during CT enhancement examinations. A total of 7,247 patients undergoing CT enhancement examinations in our department between August 2022 and May 2023 were selected. The 3,615 patients treated between August 2022 and December 2022 served as the control group, while the 3,152 patients treated from January 2022 to May 2022 were the research group. The research group received integrated care, while the control group received conventional care. The incidence and severity of iodine contrast extravasation and patient satisfaction with nursing care in the two groups were compared. The incidence of iodine contrast extravasation in the research group (0.27%) was lower than in the control group (0.94%), and the nursing satisfaction rate in the research group (99%) was higher than in the control group (90%). The differences were statistically significant (P < 0.05). The use of integrated care in CT enhancement examinations can effectively reduce the incidence of iodine contrast extravasation and improve patient satisfaction with nursing care.
Keywords
CT; Enhancement Examination; Contrast Agent; Extravasation; Satisfaction
References
[1] REN Li, ZHU Ying, SHI Suping, FU Kui, LI Ke. Analysis of Adverse Reactions Due to Non-ionic Contrast Agent Injection Rate in CT Enhanced Scanning. Chinese Journal of Medical Computer Imaging, 2022, 22(05): 488-490. [2] GU Wencui, LIN Hongxia. Analysis of Influencing Factors of Contrast Agent Leakage after CT Enhanced Scanning. China Medical Herald, 2022, 19(01): 162-165. [3] HUANG Chaoqiong, ZENG Yongming, CHEN Hongling, HUANG Yang, WU Jiahui. Analysis of Factors and Correlation of Iodine Contrast Agent Leakage in CT Enhanced Scanning. Chongqing Medicine, 2017, 46(27): 3789-3791. [4] LIAO Weihua, CEN Feng, LIANG Fengpan, LI Lianying, ZHAO Jingjie. Study on the Effects of Different Vein Injection Sites and Rates on the Upper Limb to Prevent Contrast Agent Extravasation. Journal of Practical Medical Imaging, 2018, 19(06): 512-513. [5] DING S, MEYSTRE N R, CAMPEANU C, et al. Contrast media ex-travasatio in patients undergoing computerized tomography scan-ning: a systematic review and meta-analysis of risk factors and interventions. JBI Database System Rev Implement Rep,2018,16(1):87-116. [6] ZHANG Xueyan, CHEN Qiumei, LIU Lianqing. Nursing Strategies for Contrast Agent Extravasation in Imaging Examinations Enhanced Scanning. General Nursing, 2019, 13(08): 737-738. [7] LIU Yujun, LI Mei, CHEN Jing, HE Xiaoyan, HUANG Xiaoping. Process Quality Control to Reduce Iodine Contrast Agent Extravasation Rate in CT Enhanced Scanning. Nursing Journal, 2017, 24(03): 25-27. [8] LIANG Junli, HUANG Hongfang, CHEN Xiuzhen, DOU Ying, PAN Xiping. Application of Evidence-based Nursing in Multidisciplinary Collaboration for CT Enhanced Iodine Contrast Agent Extravasation Treatment. Proceedings of the Chinese Medical Equipment Conference and 2022 Medical Equipment Exhibition (Volume I). [Publisher Unknown], 2022: 240-245. [9] ZHANG Li, Application of Iterative Reconstruction Technology (AIDR3D) in Low Radiation Dose Cervical CT Angiography. Cangzhou Central Hospital, Hebei Province, 2017-05-08. [10] WEN Xueke, ZHANG Bin, LUO Chunliu, et al. Research Progress on Nursing Interventions for Iodine Contrast Agent Extravasation in CT Enhanced Scanning. Nurse Advanced Studies Journal, 2020, 35(17): 1584-1587. [11] LI Xue, ZHENG Shumei, QU Meixiang. Expert Consensus on the Safety of Iodine Contrast Agent Infusion in Radiology. Interventional Radiology Journal, 2018, 27(08): 707-712. [12] WANG Rongfang, XIANG Fawei, SUN Xiqin. The Effect of Temperature on Adverse Reactions of Iodine Contrast Agent. Qilu Nursing Journal, 2011, 17(03): 36-37. [13] GUAN Hua. Analysis of the Causes and Nursing Measures of Contrast Agent Extravasation in Patients Undergoing CT Enhanced Scanning. General Nursing, 2015, 13(01): 13-15. [14] DING Lanying. Risk Factors and Intervention Measures for Vascular Extravasation of Iodine Contrast Agent in CT Enhanced Scanning. Primary Medical Forum, 2014, 18(01): 83-84. [15]F.J. Pacheco Compaña and B. Gago Vidal and C. Méndez Díaz. Extravasation of contrast media at the puncture site: Strategies for management. Radiología (English Edition), 2014, 56(4): 295-302. [16] SUN Cunjuan, KAN Hong, TONG Min, WEN Yu. The Effect of Iodine Contrast Agent Thermostat Heating on Adverse Reactions, Examination Comfort, and Image Quality of CT Enhanced Scanning. Journal of North Sichuan Medical College, 2022, 37(07): 943-946.
Copyright @ 2020-2035 STEMM Institute Press All Rights Reserved